Commercial Lighting & LED Retrofits
Commercial lighting & LED retrofits that cut energy costs and improve light quality for Bergen County businesses. Call (201) 391-7759.
Pascale Electric, Inc. — 130 Kinderkamack Road, Park Ridge, NJ 07656.
Call (201) 391-7759
or email info@pascaleelectric.com.
The short answer
A commercial LED retrofit replaces fluorescent, HID or older LED lighting with current LED sources and the controls the energy code requires, lowering energy and maintenance demand while improving light quality and color consistency. The three real paths are a lamp-level swap, a listed retrofit kit installed in the existing luminaire, and full luminaire replacement — and they differ in labor, light distribution, controls capability and how long the result lasts. If a utility incentive is part of the plan, the sequence matters: custom and performance-based projects generally require program approval before equipment is purchased and installed.
Commercial Lighting & LED Retrofit — key facts
- After-hours capable
- Most retrofits are done outside business hours, area by area, so the space is fully lit and open every morning. Occupied offices, retail floors and warehouses rarely need to close.
- Utility pre-approval
- Prescriptive incentives are generally tied to pre-qualified equipment lists. Custom and performance-based projects typically require program approval, and sometimes a pre-inspection, before purchase and installation.
- Permit picture
- A like-for-like fixture swap can fall under ordinary maintenance — but that exemption does not cover fixtures containing emergency battery packs, and any new circuiting or control wiring is permitted work.
- Energy-code trigger
- Replacing the lighting system in a space brings that space under current energy-code lighting-control requirements, so controls should be designed in from the start rather than added later.
- Product qualification
- Utility programs generally require DesignLights Consortium (DLC) qualified products or ENERGY STAR listing. DLC qualification establishes product eligibility — it is not the same as project approval.
You need this if
- Your electric bill keeps climbing and lighting runs for most of the hours your building is occupied.
- You are still relighting T8s, T12s or metal halide, and lamp-and-ballast replacement has become a recurring maintenance line item.
- The space looks tired — mismatched color temperature, dim corners, buzzing or flickering fixtures — and it is affecting how customers or tenants perceive the property.
- A warehouse or high-bay space needs a lift every time a lamp fails, so each individual failure is disproportionately expensive to fix.
- Your emergency and egress lighting is aging, failing its monthly test, or has no written test record at all.
- You want to pursue a utility efficiency incentive and need someone who understands the program sequence before you buy equipment.
Commercial Lighting & LED Retrofit
Switching to LED cuts energy and maintenance costs while improving how a space looks and feels. We retrofit and upgrade lighting as part of our commercial and industrial electrical work — interior and exterior — and can help you take advantage of available efficiency programs.
What we do
Interior and exterior LED retrofits, new fixtures and controls, occupancy sensors, and lighting upgrades for offices, retail, and warehouses. Exterior work extends to parking lot and pole lighting, where dusk-to-dawn hours multiply the savings.
How the job runs
- Lighting audit and fixture count
- We walk the property and inventory what is actually installed — fixture type, lamp and ballast configuration, mounting, ceiling condition, operating hours by area, and existing controls. This is the document everything else is built on, and it is where fixture counts that were guessed from a floor plan get corrected.
- Retrofit strategy per area
- Different spaces get different answers. An open office with clean lay-in troffers may suit retrofit kits; a warehouse with corroded HID housings usually justifies full luminaire replacement; a customer-facing retail floor is often driven by appearance and color quality. We give you a per-area recommendation with the reasoning, not one product applied everywhere.
- Controls design to the energy code
- We identify what the energy code requires for each space type — manual control, automatic shutoff when unoccupied, time-of-day scheduling, daylight-responsive control in daylit zones, and exterior shutoff — and design the control layout before the fixtures are ordered, because controls drive the wiring.
- Incentive sequencing, if you are pursuing one
- Programs are administered by the utility that bills your meter, and the rules are specific. Prescriptive measures run off pre-qualified equipment lists; custom and performance projects generally need program approval before you purchase and install, and may require a pre-inspection. We identify what applies and make sure the installation schedule does not get ahead of the program requirements.
- Phased installation outside business hours
- We work area by area, at night or on weekends, so no part of the property is dark during operations. Ceilings are reinstated as we go, lamps and ballasts are removed and handled through proper recycling channels, and each area is verified lit and controlled before we leave it.
- Commissioning, walkthrough and documentation
- Sensors get their time delays and sensitivity set, schedules get programmed, daylight zones get calibrated, and we walk the property with you at night and during the day. Converted fixtures receive the retrofit kit's field-applied labels, and you get the fixture schedule and any documentation your incentive program requires.
What's included
- Full property lighting audit with fixture-by-fixture inventory and operating-hour assumptions by area
- Per-area retrofit strategy — lamp-level, listed retrofit kit, or full luminaire replacement — with the reasoning stated
- Lighting-control design and installation to meet the energy code for each space type
- Phased, after-hours installation so occupied areas stay lit and open
- Field-applied labeling of converted luminaires as the retrofit kit listing requires
- Removal and proper recycling handling of replaced lamps and ballasts
- Commissioning of sensors, schedules and daylight zones, plus a joint walkthrough
- Documentation package supporting any utility incentive application
What's not included
- Guarantees of a specific energy reduction — real numbers require metered data and a program-grade savings analysis, which the utility's own engineering review performs on custom projects
- Utility incentive approval itself, which is the program administrator's decision and subject to their terms and program-year budget
- Ceiling grid and tile replacement beyond reinstating what we open, and repair of ceilings already damaged before we arrived
- Painting, patching or finish work where old fixture footprints differ from the new ones
- Structural reinforcement for heavier fixtures, and any roofing penetration work
- Networked lighting-control software licensing, IT network provisioning and ongoing platform subscriptions
- Asbestos or hazardous-material abatement, which must be cleared by a licensed abatement contractor first
What affects the cost
- Fixture count and fixture type
- The single largest driver. A count taken from a real walkthrough rather than a floor plan is also the difference between a proposal that holds and one that grows.
- Mounting height and lift requirements
- Lay-in troffers at nine feet are quick. High-bay warehouse fixtures require lifts, lift delivery and return, floor protection, and clearing aisles or racking to get the lift where it needs to be.
- Retrofit path chosen
- Lamp-level swaps carry the least labor and the most compromise. Listed retrofit kits sit in the middle. Full luminaire replacement costs the most per fixture but delivers published photometrics, a single warranty, and a fixture that is not limited by the condition of a twenty-year-old housing.
- Existing ceiling and housing condition
- Stained, sagging or damaged grid and corroded exterior or damp-location housings often make retrofitting the false economy — the assembly still looks and performs like the old fixture even with a new light source in it.
- Controls scope
- Standalone occupancy sensors and a photocell are modest. Daylight-responsive zones, time-of-day scheduling across many areas, and networked control systems add wiring, commissioning and programming time.
- After-hours and occupied-space access
- Working nights and weekends around merchandise, workstations, patients or inventory means more mobilizations, more protection and more setup time than the same fixture count in an empty building.
- Circuit and wiring condition
- If the existing lighting circuits and switch legs support the new controls, the work is fixture-side. If they do not — no neutral at the switch, no control conductor, or overloaded circuits — the scope extends into the branch circuiting.
Lamp swap vs. listed retrofit kit vs. new luminaire
- Labor per fixture — Lamp-level swap: Lowest — Listed retrofit kit: Moderate — the fixture is opened and reworked — New luminaire: Highest per fixture, but often competitive at volume
- Existing ballast — Lamp-level swap: May remain in circuit, which keeps a known failure point and adds a conversion loss — Listed retrofit kit: Typically removed or bypassed — New luminaire: Gone entirely
- Photometrics — Lamp-level swap: Reuses optics designed for a different source; no published IES file for the result — Listed retrofit kit: Kit is tested with the host, but options are limited to listed hosts — New luminaire: Manufacturer IES file available — the only path when a lighting plan or calculation is required
- Dimming and controls — Lamp-level swap: Most limited — Listed retrofit kit: Good, depending on the driver arrangement — New luminaire: Best — full dimming and networked control options
- Lifetime ceiling — Lamp-level swap: Bounded by the host housing, sockets and seals — Listed retrofit kit: Bounded by the host housing, sockets and seals — New luminaire: Set by the new fixture, not the old one
- Appearance — Lamp-level swap: The old fixture, relamped — Listed retrofit kit: The old fixture with a new interior — New luminaire: New, and the honest choice where stained or damaged housings are visible to customers
- Warranty — Lamp-level swap: Split across lamp maker and host — Listed retrofit kit: Split across kit maker and host — New luminaire: Single manufacturer for the whole luminaire
Permits and code
- NEC 410.6 requires retrofit kits to be listed. A kit assembled in the field from unlisted components does not comply, and a listed kit is certified either for specific luminaire models or for a defined generic host type spelled out in the kit's installation instructions.
- UL 1598C is the standard for LED retrofit luminaire conversion kits. Kits ship with field-applied labels to be affixed to the host luminaire after conversion, and installing a certified kit does not void the host luminaire's original listing. A lamp carrying only a general listing has not necessarily been investigated for luminaire conversion.
- New Jersey's energy subcode routes commercial buildings through ASHRAE Standard 90.1, which sets lighting power allowances and a space-by-space control matrix. Where a space receives a total replacement or newly installed lighting system, that space must meet the current control requirements — which is why a retrofit is rarely just a fixture change.
- Ordinary maintenance in New Jersey covers like-for-like replacement of a lighting fixture, but explicitly excludes fixtures containing emergency battery packs. Replacing emergency or combination exit/emergency fixtures is permitted work, not maintenance.
- Egress illumination must be supported by emergency power for not less than 90 minutes, and emergency lighting equipment is subject to a periodic testing regimen — a short monthly functional test and an annual full-duration test — with written records kept for the authority having jurisdiction. Exit signs must likewise remain illuminated from a reliable secondary power source, other than approved self-luminous and listed photoluminescent types. Self-testing and self-diagnostic fixtures are a recognized way to automate the testing.
In Bergen County & the Pascack Valley
Which incentive programs a Bergen County business can even apply to depends on which utility bills its meter, and northern Bergen County is unusually fragmented. Businesses in Woodcliff Lake, Hillsdale, Westwood, Emerson and Washington Township are generally PSE&G electric customers. Montvale — including the corporate campuses around Sharp's U.S. headquarters, Benjamin Moore, KPMG and Ingersoll Rand — along with Allendale, Ramsey, Franklin Lakes and Upper Saddle River sits in Rockland Electric (Orange & Rockland) territory. Park Ridge is served by its own borough-owned Electric Department. River Vale and Saddle River are split, sometimes within the same street. Both PSE&G and Rockland Electric run commercial and industrial programs with prescriptive, custom and small-business direct-install tracks, and the terms are set per program year — so the first question on any retrofit here is not what fixture to buy, it is whose program you are in. The retrofit work itself is familiar territory: Route 17 retail, the Kinderkamack Road business strip, the storefronts on Westwood Avenue and in downtown Ramsey, the open-air centers like Tice's Corner Marketplace, and the office and light-industrial buildings scattered through the Pascack Valley.
Commercial Lighting & LED Retrofit FAQs
- Are there rebates for LED upgrades?
- New Jersey utilities periodically offer efficiency incentives.
- Should we install first and apply for the incentive afterward?
- For custom and performance-based projects, usually no — and this is the single most common and most expensive mistake we see. Utility program guides for custom measures generally state that program approval is required prior to purchase and installation, and some programs also require a pre-inspection to establish the existing baseline. Installing first can forfeit eligibility outright, because there is no longer a baseline to measure against. Prescriptive measures on pre-qualified equipment lists work differently. Confirm the sequence with the program before anything is ordered.
- What is DLC qualification and why does the utility keep asking about it?
- The DesignLights Consortium maintains a qualified products list for commercial and industrial lighting and controls, with tested thresholds for efficacy, color rendering, lumen maintenance, power factor and harmonic distortion. Utility programs across North America use it as a rebate-eligibility gate because it gives them a pre-vetted, auditable basis for claiming energy savings. The distinction worth holding onto: DLC qualification establishes that a product is eligible. It does not mean your project is approved — that is a separate program decision.
- Will the space actually be as bright after the retrofit?
- It depends on the path. A full luminaire replacement can be designed to a target light level because the manufacturer publishes photometric data for the fixture. A lamp-level swap inside a housing whose reflectors and optics were designed around a fluorescent or HID source will distribute light differently than the original, and the resulting assembly typically has no published photometric file. That is fine in many general-purpose spaces and a real problem anywhere a light level has to be calculated or demonstrated. We flag which areas fall into which category during the audit.
- Do the emergency and exit fixtures get handled in the same project?
- They should be, and they are treated differently from the rest of the lighting. Replacing a fixture containing an emergency battery pack is not ordinary maintenance in New Jersey, so it is permitted work. Egress illumination has to hold up for at least 90 minutes on emergency power, exit signs need a reliable secondary source, and both are subject to periodic testing with written records the authority having jurisdiction can ask to see. If your building has no test record, a retrofit is the natural moment to establish one.
- Can this be done without closing or disrupting our operations?
- In nearly every case, yes. We work area by area outside your business hours — nights for offices and retail, off-shift for warehouses and light industrial — and we complete each area before moving on, so nothing is left half-lit when you open. Where an area is genuinely too large to finish in one shift, we stage temporary lighting. Ceilings get reinstated the same night, and the floor is clean and clear before your people walk in.
- Our fixtures are only a few years old. Is a retrofit still worth looking at?
- Sometimes the fixtures are not the opportunity — the controls are. Early LED installations frequently went in as straight one-for-one replacements with no occupancy sensing, no scheduling and no daylight response, which leaves fully lit spaces running through hours nobody occupies them. Adding controls to serviceable fixtures is often the smaller project with the more direct effect on consumption. The audit tells us which situation you are in, and we would rather tell you the fixtures are fine than sell you a full replacement you do not need.
Towns we serve
- Electrician in Park Ridge, NJ
- Electrician in Woodcliff Lake, NJ
- Electrician in Montvale, NJ
- Electrician in Hillsdale, NJ
- Electrician in River Vale, NJ
- Electrician in Westwood, NJ
- Electrician in Washington Township, NJ
- Electrician in Emerson, NJ
- Electrician in Oradell, NJ
- Electrician in Upper Saddle River, NJ
- Electrician in Saddle River, NJ
- Electrician in Franklin Lakes, NJ
- Electrician in Wyckoff, NJ
- Electrician in Allendale, NJ
- Electrician in Ramsey, NJ